New Merchandise Flash: EcoBreeze from APC by Schneider Electric

2010-11-18

APC by Schneider electrical has released EcoBreeze™, a modular indirect evaporative and air-to-air heat exchanger cooling remedy for information centers. The EcoBreeze can change instantly in between air-to-air and indirect evaporative heat swap to consistently provide cooling within of one of the most effective method to the present conditions.

EcoBreeze from APC by Schneider electrical is sited outside the information center.

The design in the EcoBreeze serves to cut back vitality usage by leveraging temperatures variations in between outside ambient oxygen in comparison to IT return oxygen to provide economized cooling to some information center.

The EcoBreeze addresses the necessities of today’s information center’s by implementing several types of economization into each and every module. The unit, situated outside the perimeter in the information center, requires benefit of localized climates and will instantly change in between two types of economized cooling:

Air-to-air heat swap — delivers in warm IT oxygen in within of the information center by making use of the modules EC (Electronically Commutated) fans that is then passed by making use of inside channels in the Indirect Evaporative Cooler (IEC). appropriate after the IT oxygen is cooled it leaves the IEC and passes by making use of a cooling coil and returned toward the information center.

Indirect evaporative heat swap — When ambient temperatures cannot help an air-to-air heat exchange, cooling is achieved by making use of indirect evaporative cooling which removes heat within of the IT oxygen by evaporating consuming water for the outside in the heat exchanger channels.

The EcoBreeze could possibly be the 1st remedy for the industry which prevents the outside oxygen from coming in make contact with using the information center air, regardless of which cooling mode is employed (air-to oxygen or indirect evaporative).

The EcoBreeze features a proportional R410a refrigerant method as well as an on-board consuming water treatment system, eliminating the prerequisite for substance consuming water treatment. This element addresses environmental concerns associated to some refrigerant or consuming water dependent systems. the two in the economization cooling methods employed maximize localized environment problems to be certain one of the most effective and effective type of cooling year-round.

The EcoBreeze meets ASHRAE 90.1/TC 9.9 specifications for ability and economization with several frame sizes with various voltages and levels to serve all information center cooling needs. It is on the marketplace person 50kw modules that could possibly be grouped as a good offer as 4 modules (200kw) or eight modules (400kw) of sensible cooling. The modular, scalable method allows managers to purchase only what they should satisfy latest cooling requirements. This modularity also provides redundancy on the frame level and guarantees availability in the method even by making use of upkeep and provider intervals. Power, water, oxygen flow distribution, and discussion connections are centralized toward the frame. Additionally, the system is situated outside the perimeter in the information center, so it does not occupy space within of the information center itself.