News
The maintenance and modification of the condenser
2011-7-171.Replace lengthened condenser coils
2.Water tank and condenser cooling fan circuit modification.If it impact engine cooling,please use thickened water tank.If you want better cooling,please extend your water tank and make condenser fan and water tank cooling operate together.
3.Strengthen the engine cooling,then modified strengthen water tank cooling and condenser fan.
4.Clean condenser coils and replace liquid storing tube.Choose the correct viscosity and high quality refrigeration liquid.It can make the temperature falling about 2 to 4 degress.
5.Modification asjustable-cooling switch to use the manual adjustment of air temperature.
Previous News >> Air bearing heat exchanger
Next News >> The reason of refrigerator evaporator leakage and solving methods